0086-519-85503555sales@beich.com.cn
CH906A&CH906D
CH906A&CH906D

CH906A&CH906D

An instrument that integrates charge and discharge and can completely simulate the charge and discharge process of batteries.
Product Detail

CH906 series analog battery tester is a newly introduced instrument of our company, which integrates charging and discharging, and can fully simulate the charging and discharging process of the battery. The power supply adopts linear power supply mode, which ensures the low ripple noise of the output power supply, and can replace the battery to test the function or performance of PCBA board of ordinary adapter or mobile power supply. It is mainly used in the development and experiment of battery charging and discharging products such as mobile power supply, adapter, Bluetooth headset and Bluetooth speaker, and can also be used as a common adjustable power supply. Its input/output voltage and input/output current protection values can be set in multiple groups.

Features:

1. 4.3-inch high-definition TFT touch screen, with numeric keypad and knob to set data quickly.

2. Adopt linear power supply to ensure low ripple noise of output power supply.

3. At the same time, it has the functions of charging and discharging the battery, and can automatically switch infinitely.

4. 6 groups of voltage and current preset storage functions, which can be quickly called with one key.

5. The voltage is 1mV, the current is 1mA, the display resolution is high, and the standby current of PCBA or finished products can be detected.

6. Remote measurement interface to ensure the test accuracy.

7. The standard U disk interface can be used for data storage and system update.

8. RS232C communication interface is standard, and various baud rates are optional.

9. Standard shelf size is convenient for system integration.

model

CH906A

CH906D



Parameter range and accuracy

Output (discharge)

voltage

0.1~20V

0.1~10V

current

0~10A

0~2A

Input (charging)

voltage

0.2~20V

0.2~10V

current

0.1~10V0~10A 10.01~20V0~5A

0~2A

Set resolution

voltage

0.1~5V1mV 5.01~20V5mV

1mV

current

1mA

1mA

Setting accuracy

voltage

0.1~5V0.05%+2mV

0.05%+2mW

5.01-20V0.05% +10mV

Readback resolution

voltage

0.1-5.0V1mV

1mV

5.01-20V5mV

current

0-10mA(Low range)0.0001mA

0-10mA(Low range):0.0001mA

10mA-10A(High range)0.1mA

10mA-2A(High range):0.1mA

Readback accuracy

voltage

0.1-5V0.05% +2mV

0.05%+2mV

5.01-20V0.05% +10mV

current

0-10mA(低量程):: 0.1% +1uA

0-10mA:0.1%+1uA

10mA-10A(高量程)0.1% +3mA

10mA-2A:0.1%+3mA

Load adjustment rate

voltage

<0.06%

Power supply adjustment rate

voltage

<0.05%

ripple

voltage

Max60mV

Input power supply

ACvoltage

110V/220Vac

outline dimension


230mmD*350mmW*88mmH

weight


about 7Kg

about 4kg